Multi-parameter patient monitors use proprietary multi-pin connectors aggregating ECG SpO2 NIBP temperature and IBP cabl
AED defibrillation pad connectors carry high-voltage shock energy and low-level ECG sensing signals through the same con
Ultrasound transducer connectors are complex multi-pin assemblies (64 to 256 pins) connecting piezoelectric arrays to th
ECMO (Extracorporeal Membrane Oxygenation) circuit connectors use Luer lock and push-fit hemostatic connectors for blood
Bipolar electrosurgery connectors carry RF current between two jaws of bipolar forceps, with the current passing only th
Monopolar electrosurgery active electrode connectors carry RF cutting and coagulation energy at 300-500 kHz from the ele
Standard 4mm snap electrodes connect disposable adhesive ECG/EEG electrodes to lead wires. The snap mechanism allows qui
Luer lock connectors are the standard medical fluid connection between infusion pump tubing, IV catheters, syringes, and
Pulse oximeter probes connect to monitors via DB9 connectors carrying LED drive signals for red and infrared LEDs and th
NIBP cuff connectors use a 2.5mm or 3.5mm sterile pneumatic fitting to connect disposable blood pressure cuffs to patien
Amphenol medical connectors include the M-Series and G-Series specifically designed for patient-connected and body-worn
ITT Cannon medical-grade D-sub connectors meet IEC 60601-1 creepage and clearance requirements for patient-connected equ
ITT Cannon medical-grade D-sub connectors meet IEC 60601-1 creepage and clearance requirements for patient-connected equ
BNC panel connectors on DAQ instruments provide individual channel access for oscilloscopes, spectrum analyzers, and dat
Souriau 851 series are military-grade circular connectors used in medical, defense, and industrial equipment where MIL-s
Load cell 6-wire connections add remote sense wires that allow the amplifier to compensate for voltage drop in long exci
LVDT (Linear Variable Differential Transformer) position sensors use 5-wire connections: primary excitation AC and four
Incremental encoders commonly use 5-pin DIN connectors carrying power, ground, and A/B quadrature signals plus index pul
Measurement Computing DAQ boards use a DB37 D-sub connector providing analog inputs, analog outputs, digital I/O, and co
pH electrodes connect to pH meters and transmitters via BNC connectors. The high-impedance glass electrode produces a mi
Strain gauge Wheatstone bridge sensors use 4-wire connections for excitation and signal to eliminate lead resistance err
Standard thermocouple connectors are larger flat-blade polarized connectors used on panel-mounted instruments and fixed
PT100 RTD (Resistance Temperature Detector) 4-wire connections eliminate lead resistance error from precision temperatur
Miniature thermocouple connectors (ANSI color-coded) are small flat-blade polarized connectors for thermocouples in port