← All Components  /  Medical Scientific Connectors
// Medical Scientific Connectors

Measurement Computing 37-Pin

Measurement Computing DAQ boards use a DB37 D-sub connector providing analog inputs, analog outputs, digital I/O, and counter/timer connections for USB and PCIe data acquisition devices.

// Specifications
Standard
Measurement Computing DB37
Connector
DB37 D-sub 37-pin
Channels
16 AI 2 AO 24 DIO 2 counters typical
Interface
USB or PCIe
Use Case
Lab DAQ MCC USB-1208 USB-1608 series
Software
Universal Library or DAQFlex
// Pin Reference Table
Pin Name Function Type
1 CH0 Analog input channel 0 ADC
2 CH1 Analog input channel 1 ADC
3 CH2 Analog input channel 2 ADC
4 CH3 Analog input channel 3 ADC
19 AGND Analog ground GND
20 AO0 Analog output 0 ADC
21 AO1 Analog output 1 ADC
22 DGND Digital ground GND
23 D0 Digital port 0 bit 0 I/O
24 D1 Digital port 0 bit 1 I/O
37 +5V 5V digital supply PWR